215 changes: 142 additions & 73 deletions bsp/stm32/libraries/HAL_Drivers/drivers/Kconfig
Original file line number Diff line number Diff line change
Expand Up @@ -196,10 +196,9 @@ menu "STM32 Input Capture BSP"
default n
select RT_USING_INPUT_CAPTURE
help
Registers selected STM32 hardware timer Input Capture devices.
F1 and H7 have configuration headers; additional series need a
matching configuration header before enabling this option.
GPIO, clock and interrupt setup are owned by CubeMX HAL IC MSP.
Register independently selected timer capture channels, or one
exclusive hardware PWM Input or dual-edge device per enabled TIM.
Configure capture pins, peripheral clocks and IRQ in the board HAL MSP.

if BSP_USING_INPUT_CAPTURE
config BSP_INPUT_CAPTURE_COUNTER_HZ
Expand All @@ -212,101 +211,171 @@ menu "STM32 Input Capture BSP"
default n

if BSP_USING_INPUT_CAPTURE_TIM1
config BSP_INPUT_CAPTURE_TIM1_NAME
string "TIM1 Input Capture device name"
default "ic1"

config BSP_INPUT_CAPTURE_TIM1_CHANNEL
int "TIM1 Input Capture channel (1-4)"
range 1 4
default 1

config BSP_INPUT_CAPTURE_TIM1_FILTER
int "TIM1 Input Capture digital filter (0-15)"
range 0 15
default 0

config BSP_INPUT_CAPTURE_TIM1_INITIAL_RISING
int "TIM1 initial capture edge (1 rising, 0 falling)"
config BSP_INPUT_CAPTURE_TIM1_PWM_INPUT
int "TIM1 PWM Input (0 = off, 1 = on)"
range 0 1
default 1
default 0
help
PWM Input occupies the entire timer and registers one
logical capture device. Set 0 to select dual-edge or
independent EDGE capture instead.

config BSP_INPUT_CAPTURE_TIM1_DUAL_EDGE
bool "TIM1 paired dual-edge capture (CH1/CH2)"
depends on BSP_INPUT_CAPTURE_TIM1_PWM_INPUT = 0
default n
help
Capture rising and falling edges of the same TI1/TI2 input
with CH1/CH2 and register one logical device. This mode
reserves the entire timer and does not use slave reset.

if BSP_INPUT_CAPTURE_TIM1_PWM_INPUT = 0 && !BSP_INPUT_CAPTURE_TIM1_DUAL_EDGE
config BSP_INPUT_CAPTURE_TIM1_CH1
bool "TIM1 CH1 independent EDGE capture"
default y
config BSP_INPUT_CAPTURE_TIM1_CH2
bool "TIM1 CH2 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM1_CH3
bool "TIM1 CH3 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM1_CH4
bool "TIM1 CH4 independent EDGE capture"
default n
endif
endif

config BSP_USING_INPUT_CAPTURE_TIM2
bool "Enable TIM2 Input Capture"
default n

if BSP_USING_INPUT_CAPTURE_TIM2
config BSP_INPUT_CAPTURE_TIM2_NAME
string "TIM2 Input Capture device name"
default "ic2"

config BSP_INPUT_CAPTURE_TIM2_CHANNEL
int "TIM2 Input Capture channel (1-4)"
range 1 4
default 1

config BSP_INPUT_CAPTURE_TIM2_FILTER
int "TIM2 Input Capture digital filter (0-15)"
range 0 15
default 0

config BSP_INPUT_CAPTURE_TIM2_INITIAL_RISING
int "TIM2 initial capture edge (1 rising, 0 falling)"
config BSP_INPUT_CAPTURE_TIM2_PWM_INPUT
int "TIM2 PWM Input (0 = off, 1 = on)"
range 0 1
default 1
default 0
help
PWM Input occupies the entire timer and registers one
logical capture device. Set 0 to select dual-edge or
independent EDGE capture instead.

config BSP_INPUT_CAPTURE_TIM2_DUAL_EDGE
bool "TIM2 paired dual-edge capture (CH1/CH2)"
depends on BSP_INPUT_CAPTURE_TIM2_PWM_INPUT = 0
default n
help
Capture rising and falling edges of the same TI1/TI2 input
with CH1/CH2 and register one logical device. This mode
reserves the entire timer and does not use slave reset.

if BSP_INPUT_CAPTURE_TIM2_PWM_INPUT = 0 && !BSP_INPUT_CAPTURE_TIM2_DUAL_EDGE
config BSP_INPUT_CAPTURE_TIM2_CH1
bool "TIM2 CH1 independent EDGE capture"
default y
config BSP_INPUT_CAPTURE_TIM2_CH2
bool "TIM2 CH2 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM2_CH3
bool "TIM2 CH3 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM2_CH4
bool "TIM2 CH4 independent EDGE capture"
default n
endif
endif

config BSP_USING_INPUT_CAPTURE_TIM3
bool "Enable TIM3 Input Capture"
default y

if BSP_USING_INPUT_CAPTURE_TIM3
config BSP_INPUT_CAPTURE_TIM3_NAME
string "TIM3 Input Capture device name"
default "ic3"

config BSP_INPUT_CAPTURE_TIM3_CHANNEL
int "TIM3 Input Capture channel (1-4)"
range 1 4
default 1

config BSP_INPUT_CAPTURE_TIM3_FILTER
int "TIM3 Input Capture digital filter (0-15)"
range 0 15
default 0

config BSP_INPUT_CAPTURE_TIM3_INITIAL_RISING
int "TIM3 initial capture edge (1 rising, 0 falling)"
config BSP_INPUT_CAPTURE_TIM3_PWM_INPUT
int "TIM3 PWM Input (0 = off, 1 = on)"
range 0 1
default 1
default 0
help
PWM Input occupies the entire timer and registers one
logical capture device. Set 0 to select dual-edge or
independent EDGE capture instead.

config BSP_INPUT_CAPTURE_TIM3_DUAL_EDGE
bool "TIM3 paired dual-edge capture (CH1/CH2)"
depends on BSP_INPUT_CAPTURE_TIM3_PWM_INPUT = 0
default n
help
Capture rising and falling edges of the same TI1/TI2 input
with CH1/CH2 and register one logical device. This mode
reserves the entire timer and does not use slave reset.

if BSP_INPUT_CAPTURE_TIM3_PWM_INPUT = 0 && !BSP_INPUT_CAPTURE_TIM3_DUAL_EDGE
config BSP_INPUT_CAPTURE_TIM3_CH1
bool "TIM3 CH1 independent EDGE capture"
default y
config BSP_INPUT_CAPTURE_TIM3_CH2
bool "TIM3 CH2 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM3_CH3
bool "TIM3 CH3 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM3_CH4
bool "TIM3 CH4 independent EDGE capture"
default n
endif
endif

config BSP_USING_INPUT_CAPTURE_TIM4
bool "Enable TIM4 Input Capture"
default n

if BSP_USING_INPUT_CAPTURE_TIM4
config BSP_INPUT_CAPTURE_TIM4_NAME
string "TIM4 Input Capture device name"
default "ic4"

config BSP_INPUT_CAPTURE_TIM4_CHANNEL
int "TIM4 Input Capture channel (1-4)"
range 1 4
default 1

config BSP_INPUT_CAPTURE_TIM4_FILTER
int "TIM4 Input Capture digital filter (0-15)"
range 0 15
default 0

config BSP_INPUT_CAPTURE_TIM4_INITIAL_RISING
int "TIM4 initial capture edge (1 rising, 0 falling)"
config BSP_INPUT_CAPTURE_TIM4_PWM_INPUT
int "TIM4 PWM Input (0 = off, 1 = on)"
range 0 1
default 1
default 0
help
PWM Input occupies the entire timer and registers one
logical capture device. Set 0 to select dual-edge or
independent EDGE capture instead.

config BSP_INPUT_CAPTURE_TIM4_DUAL_EDGE
bool "TIM4 paired dual-edge capture (CH1/CH2)"
depends on BSP_INPUT_CAPTURE_TIM4_PWM_INPUT = 0
default n
help
Capture rising and falling edges of the same TI1/TI2 input
with CH1/CH2 and register one logical device. This mode
reserves the entire timer and does not use slave reset.

if BSP_INPUT_CAPTURE_TIM4_PWM_INPUT = 0 && !BSP_INPUT_CAPTURE_TIM4_DUAL_EDGE
config BSP_INPUT_CAPTURE_TIM4_CH1
bool "TIM4 CH1 independent EDGE capture"
default y
config BSP_INPUT_CAPTURE_TIM4_CH2
bool "TIM4 CH2 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM4_CH3
bool "TIM4 CH3 independent EDGE capture"
default n
config BSP_INPUT_CAPTURE_TIM4_CH4
bool "TIM4 CH4 independent EDGE capture"
default n
endif
endif

config BSP_USING_INPUT_CAPTURE_DUAL_EDGE
bool
default y if BSP_INPUT_CAPTURE_TIM1_DUAL_EDGE
default y if BSP_INPUT_CAPTURE_TIM2_DUAL_EDGE
default y if BSP_INPUT_CAPTURE_TIM3_DUAL_EDGE
default y if BSP_INPUT_CAPTURE_TIM4_DUAL_EDGE

config BSP_USING_INPUT_CAPTURE_PWM_INPUT
bool
default y if BSP_INPUT_CAPTURE_TIM1_PWM_INPUT = 1
default y if BSP_INPUT_CAPTURE_TIM2_PWM_INPUT = 1
default y if BSP_INPUT_CAPTURE_TIM3_PWM_INPUT = 1
default y if BSP_INPUT_CAPTURE_TIM4_PWM_INPUT = 1

endif