Reads analog water meters and provides a web service that returns the read value as decimal. The needles of the analog gauges currently have to be red.
Turns
into 820.5745 so it can become
.
Please note, that this is not able to read 7-segment-displays. If you are using Home Assistant and want to read 7-segment-displays, you may want to take a look at the native 7 segments integration.
This is only a quick introduction to setting up and configuring watermeter. A more extensive documentation can be found in the howto.
version: "3.5"
services:
watermeter:
image: nohn/watermeter:latest
container_name: watermeter
volumes:
- ./watermeter/config:/usr/src/watermeter/src/config
restart: always
ports:
- "3000:3000"Save this configuration as compose.yml and start it with podman-compose up -d.
This can also be installed as Home Assistant Addon.
If you want to build the Container image locally, you can use the following command:
podman build . -t nohn/watermeterYou can access the configuration tool http://watermeter:3000/configure.php. The interface should be self explanatory. Source Image can be either in local filesystem or any HTTP(S) resource.
After configuration is done, you can access the current value at
http://watermeter:3000/
or
http://watermeter:3000/?json
or see debug information at
http://watermeter:3000/?debug
You can contribute to this project by:
- Opening an Issue if you found a bug or wish to propose a new feature
- Placing a Pull Request with bugfixes, new features etc.
Real users' meter images and configuration snippets are especially welcome. Adding them as regression tests helps to keep future updates compatible with individual setups.
To contribute an example in a pull request:
- Fork the repository and create a branch. Add an image of your meter to tests/data/variants/ with a descriptive, unique filename.
- Add a named entry to the
$variantsarray in tests/WatermeterReaderVariantTest.php, following an existing entry. Include your configuration snippet (especially digit and gauge coordinates and image processing settings), and setsourceImageto the new local image, for example__DIR__ . '/data/variants/my-meter.jpg'. - Set
lastValue,expectedReadout,expectedValue,hasErrors, andexpectedErrorsas in the existing examples. Include the correct reading visible in the image and account for any offset or threshold settings. - Run the tests as described below, then commit your image and test entry, push your branch, and open a pull request describing your meter and expected reading.
OCR fine tuning depends on the specific tesseract version. It is therefore recommended to run the tests in a container with the same tesseract version as the one used in production:
podman build . --target dev --no-cache
The reader tests require the Tesseract executable and English language data, in addition to the Composer dependencies. The PHP Tesseract package is a wrapper and does not install the executable. On Debian or Ubuntu, install them with:
sudo apt-get install tesseract-ocr tesseract-ocr-engConfirm tesseract --version works in the same environment as PHP, then run vendor/bin/phpunit tests. If Tesseract is missing from PATH, the reader reports an OCR error and falls back to the integer part of the last known reading for the digital digits.
To execute tests run
vendor/bin/phpunit watermeter is released under the GNU Affero General Public License.